เครื่องเพิ่มความชื้น
Humidifier |
 |
|
 |
| |
|
|
| |
Steam Humidifier เครื่องเพิ่มความชื้น ระบบ Steam Humidifier เป็นเครื่องเพิ่มความชื้นที่สามารถรับสัญญาณควบคุมได้หลายแบบ ทั้ง On-OFF, 0-10 Vdc, 4-20 mA เป็นต้น มีตั้งแต่ขนาด 2 kg/hr จนถึง 90 kg/hr สามารถติดตั้งเป็นระบบใหญ่ขนาดทำความชื้นรวมสูงสุดได้ถึง 900 kg/hr |
|
| |
|
|
|
|
| |
 |
 |
| |
LE Electrode Range
· Advanced software management program. The Vapac developed VOS-6 management program is a ground breaking package that ensures the long term performance of the humidifier regardless of the quality of raw water that it is supplied with.
· Capacity Range. There are units producing from 5 kg/hr to the new 55 kg/hr single cylinder unit and its twin cylinder sister unit at 110 kg/hr.
· Control. The VapaNet range of units have the ability to operate from any one of six proprietary DC analogue signals or to any BMS system using the LON open system protocol.
· Stainless Steel drip tray.
· Drain Pump. |
|
| |
|
|
|
|
| |
 |
 |
| |
LR Resistance Heater Range
LR Comfort Control
The single step LR units combine the high level of technology of the electrode boiler units, but with resistance heater elements mounted in a long life Stainless Steel cylinder, to provide a consistent and reliable low maintenance option.
LRP Close Control
Taking the high reliability levels of the single step LR unit and incorporating, thyristor controlled solid state relays the LRP units provide an instantaneously responsive, accurate proportional control system capable of ramping between 8% and 100% of maximum output. Using RO quality water and with stable temperatures this system has been operated to control tolerances of ±1%. |
|
| |
|
|
|
|
| |
| |
 |
 |
| |
LS Steam Room Unit
The VapaNet control system is designed with user interaction in mind. The LED user display on the door front incorporates clear signals. The indicators will show: Unit off, On-line,Standby,Room light/extract fan in auto run mode, Drain fault, Extract fan overload trip, Feed fault, Room high temperature alarm,Over current, Essence pump on ,Seervice routine-auto flush in progress,Room light in manual override, Extract fan in manual override. The display provides easy to read information that allows the user or engineer to ascertain exactly what is happening at any time.
Adding the Alpha Numeric Display, either in the body of the cabinet or sited remotely giving access to three lecels of information and configuration to set the unit to operate in accordance with site demand. the display can also be used as a service tool to interrogate the system, make changes, unplay and remove from site to prevent tempering,Alternatively a graphic display can provide a pictorial view of the system operation. The real time clock can be programmed for two on / off functions per day, severn days a week and also includes British Summer time change. |
|
|
|
| |
| |
| |
|
| |